Features of Pilotech Inert Gas Dryer
- Minimum footprint of 0.5 m² fits standard lab spaces
- Supports 10ml minimum sample volume for R&D
- Suitable for most common solvents, such as ethanol
- Dual-stage HEPA filters(optional) reduce cross-contamination and retain fine particles
- LCD touchscreen allows for convenient, real-time adjustment of process data
- Multiple two-fluid nozzle orifice sizes help adjust particle size
Your Leading Inert Gas Dryer Manufacturer
An inert gas dryer is designed for laboratories and pilot-scale facilities that process oxygen-sensitive materials, organic solvent formulations, or products that require controlled drying conditions. It reduces oxidation risk while supporting solvent handling and powder production. They are usually used in pharmaceutical, chemical, polymer, ceramic, and specialty material development. Before purchasing, you should confirm the feed type, required capacity, target particle characteristics, drying temperature, oxygen concentration, and solvent recovery requirements to ensure the system matches your process.
Pilotech is dedicated to the research, development, and production of inert gas spray dryers, with 21 years of experience in the field. We offer laboratory-scale and pilot-scale inert gas dryers to meet your diverse research project needs. We have three advanced production lines equipped with stamping equipment, cutting machines, and polishing machines. The superior quality of our equipment has earned us the trust of more than 6,000 users in over 70 countries and regions worldwide.

Compact system with a 500 mL/h capacity, modular nitrogen circulation, bag filtration, and solvent recovery. Ideal for limited or expensive samples, organic solvents, pharmaceutical formulations, and laboratory material screening.

Laboratory-scale system processing up to 1,500 mL/h, featuring oxygen monitoring, nitrogen circulation, solvent recovery, PLC touchscreen control, and flexible nozzle options for pharmaceutical, chemical, polymer, and research applications.

With a 3 L/h capacity, closed-loop nitrogen circulation, online oxygen monitoring, and solvent recovery, supports mini-pilot testing of organic solvent formulations, polymers, pharmaceutical intermediates, and specialty chemicals.

Pilot-scale system with a 5 L/h capacity, built-in nitrogen circulation, solvent recycle, and a wider 60–280°C inlet temperature range. Suitable for process development, scale-up studies, and pharmaceutical or chemical formulations.
A battery research lab in Munich tried to dry new energy materials dissolved in ethanol. Their old equipment suffered from high air leakage. Oxygen concentration inside the chamber often went above 8%. This caused frequent safety shutdowns and ruined expensive samples.
We delivered a custom nitrogen spray dryer designed for organic solvents. The unit operates as a fully sealed nitrogen drying system with an online oxygen monitoring sensor. The oxygen monitoring system uses a configured safety setpoint; when the oxygen concentration exceeds the set value, the equipment automatically stops heating and stops feeding. The integrated cold chiller condenses organic vapors quickly. This allows the lab to safely dry solvent through inert gas and keeps oxygen levels strictly below 2.5% throughout the whole drying process.
A pharma startup in California needed to process polymer materials dissolved in dichloromethane (DCM). DCM evaporates fast and is harmful to human health. Their old setup leaked toxic DCM vapor into the lab room and lost costly solvents constantly.
We installed a pilot-scale inert gas drying system built for dangerous solvents. This equipment uses closed recycled loops paired with a dual-stage condensation module. The system rapidly lowers the circulating gas temperature to -20°C. This cold loop condenses and collects over 95% of DCM vapor directly into a sealed collection bottle. The solution protects lab personnel from dangerous fumes and cuts raw material costs during pilot scale-up.
A natural product laboratory in Kyoto worked on extracting and microencapsulating oxygen-sensitive botanical antioxidants dissolved in ethanol. When exposed to ambient air and normal heating, the active ingredients oxidized instantly, turning brown and losing their functional properties.
We supplied a closed-loop nitrogen spray dryer. The system operates with a sealed nitrogen drying system that displaces oxygen before drying begins. Its online oxygen sensor ensures the oxygen concentration remains below 2.5% (or other values specified by the customer). The unit performs safe inert gas drying while the integrated refrigeration chiller condenses and recycles the ethanol vapor, protecting the heat-sensitive antioxidants from oxidation.
A chemical team in Manchester prepared fine catalyst powders using toluene. Toluene vapor is flammable, toxic, and expensive. Their old exhaust system vented all toluene into the atmosphere, creating fire hazards and wasting large amounts of costly chemicals every week.
We supplied a pilot drying system that features closed recycled loops. The equipment uses pure nitrogen as the drying medium, which reduces explosion risks. Its high-efficiency cooling condenser converts toluene vapor back into liquid form instantly. The lab can safely dry solvent through inert gas and recycle up to 96% of expensive toluene for their next production batch.
Inert Gas Dryer Specifications
| Parameter | Specification |
| Equipment Type | Laboratory / Pilot-Scale Inert Gas Spray Dryer |
| Application | Laboratory R&D, formulation development, process optimization, and pilot-scale testing |
| Drying Medium | Nitrogen or other compatible inert gas; compressed air may be used for aqueous solutions in supported configurations |
| System Configuration | Closed-Loop Inert Gas Circulation System |
| Capacity | 0.5L/h, 1.5L/h, 3L/h, 5L/h |
| Minimum Sample Volume | 10mL, 30mL, 100mL, related to factors such as the solid content of the material |
| Maximum Inlet Temperature | 200°C, 280°C, depending on model |
| Temperature Precision | ±1°C for mini and laboratory models; ±2°C for pilot-scale models |
| Rated Airflow | Approx. 1.5–3 m³/min |
| Atomization Method | Two-Fluid Nozzle (standard); Three-Fluid Nozzle Optional on Selected Models |
| Optional Nozzle Diameters | 0.5 / 0.8 / 1.0 / 1.5 / 2.0 mm optional, depending on model |
| Possible Particle Size Range | Approx. 1–100 μm, depending on model and material |
| Gas Circulation | Closed-Loop Nitrogen Circulation |
| Oxygen Monitoring | Online Oxygen Concentration Monitoring; Alarm and Shutdown Functions on Supported Models |
| Solvent Recovery | Condensation-Based Organic Solvent Recovery System |
| Heater Power | Approx. 1.5–9 kW, depending on model and configuration |
| Total Power | Approx. 2.5–11.5 kW, depending on model |
| Power Supply | 220 V Single-Phase or 380 V Three-Phase, 50/60 Hz, depending on model |
| Atomizer Material | SUS304 Stainless Steel or SUS316 Stainless Steel (optional) |
| Spray Chamber Material | SUS304 Stainless Steel or SUS316 Stainless Steel (optional) |
| Cyclone Separator Material | SUS304 Stainless Steel or SUS316 Stainless Steel (optional) |
| Collection Tank Material | SUS304 Stainless Steel or SUS316 Stainless Steel (optional) |
| Control System | PLC-Based Control with Touchscreen Interface on Supported Models |
| Temperature Protection | Overtemperature Protection; Blower does not stop until temp. <90℃ |
| Cleaning and Maintenance | Removable Components for Cleaning; Specific Procedures Depend on Model and Solvent Compatibility |
How Does an Inert Gas Spray Dryer Work?

Inert Gas Injection
First, fill the equipment with an inert gas to displace the air inside it until the oxygen concentration drops below the safety threshold. The target oxygen concentration depends on the solvent, material, system design, and applicable safety requirements. The system can be configured with a defined oxygen concentration setpoint based on the process and safety requirements.
Atomization and Drying
The liquid material is pumped into the atomizer at the top of the drying tower, where it is dispersed into fine droplets. The preheated inert gas stream comes into full contact with the droplets, and in just a few seconds, the organic solvents in the material evaporate, resulting in a dry powder.
Gas-Solid Separation
After the drying process, the powder is carried by the gas into a cyclone separator or a bag filter. The powder is collected and falls into a collection tank, while the exhaust gas, carrying solvent vapor, continues to flow.
Condensation and Gas Recirculation
The gas stream, which contains solvent vapor, passes through the condenser system, where the solvent is cooled, liquefied, and collected in a recovery tank. The pure, inert gas is then recirculated by a fan back into the heater to begin the next drying cycle.
Components of Inert Gas Drying Equipment
Main Drying Components
Feeding System
The feeding system consists primarily of a peristaltic pump and feed tubing. The peristaltic pump controls the feed rate of the liquid material. The feed tubing is made of materials resistant to corrosion by organic solvents, such as PTFE (optional).
Heating and Gas Handling System
This system has three key components. First is the circulating fan, which provides the power to circulate inert gas within the sealed system. The second is the electric heater. It is used to precisely set and heat the circulating gas to the target inlet temperature. The third component is the high-efficiency particulate air (HEPA) filter (optional). It filters residual particles from the circulating gas, helping prevent cross-contamination and wear on the system caused by powder particles.
Atomizer and Nozzle Assembly
This is key to converting liquid material into small droplets. Two-fluid nozzles are most commonly used in laboratory and pilot-scale Inert gas drying equipment. These nozzles break up the liquid into fine droplets using the powerful shear force generated by compressed gas. They are equipped with an automatic de-blocking needle to prevent clogging.
Drying Chamber
This is where the small droplets come into contact with the heated inert gas and dry. The chamber body is typically made of high-quality stainless steel, such as SUS304 or SUS316L (optional). The inner walls are mirror-polished to reduce wall sticking. The drying chamber is also usually equipped with sight glasses and viewing ports, allowing you to observe the atomization and drying conditions inside in real time.
Separation System
The separation system is equipped with a high-efficiency cyclone separator. It uses centrifugal force to separate gas from powder and recover the main powder product. The collection vessel is the container used to collect this powder. It is typically installed at the bottom and can be quickly removed, making it easy for you to collect the finished product.
Key Safety Features
For drying equipment that uses organic solvents, safety is the top priority. Laboratory and pilot inert gas dryers incorporate multiple safety mechanisms.
Oxygen Concentration Monitoring and Control
The oxygen concentration inside the tower is monitored in real time. If the oxygen concentration exceeds the preset safety threshold, the system will automatically trigger an alarm and forcibly suspend heating and feeding.
Inert Gas Circulation and System Sealing
The entire system features a high-standard sealing design and can typically operate under slight positive or negative pressure. By using an inert gas as the drying medium, oxygen is fundamentally isolated, thereby eliminating one of the conditions necessary for combustion or explosion.
Solvent Vapor Condensation and Recovery
It is used to condense and collect organic solvent vapors entrained in inert gas. This not only prevents the recirculation of high-concentration solvent vapors and improves the drying efficiency, but also benefits environmental protection and the health of operators.
Temperature and Pressure Monitoring
Real-time monitoring of inlet air temperature, outlet air temperature, tower pressure, and whether the system is slightly positive or negative pressure. This system uses a sensitive pressure sensor to determine whether airflow is circulating stably.
What Materials Are Suitable for an Inert Gas Dryer?
Organic Solvent-Based Solutions
For example, suspensions or solutions prepared using acetone, ethanol, dichloromethane (DCM), methanol, ethyl acetate, and other similar solvents. These solvents are flammable and explosive, whereas inert gases can displace oxygen, ensuring explosion-proof safety. If the equipment features a closed-loop system, the condenser can efficiently recover these organic solvents, saving you costs.
Oxygen-Sensitive Materials
Include certain natural plant extracts, vitamins, unsaturated fatty acids, and certain active metal powders. These materials are highly susceptible to oxidation, deterioration, or loss of activity when exposed to high temperatures and oxygen. Drying with an inert gas is more effective for preserving the chemical activity of these materials.
Toxic or Harmful Materials
For example, certain pesticide intermediates, specialty APIs, and materials containing organotoxic reagents. An inert gas dryer equipped with a closed-loop system helps prevent harmful gases or dust from escaping into the laboratory environment, thereby helping to protect the safety of laboratory personnel.
Heat-Sensitive Polymers in Solvents
Examples include drug-carrying microsphere materials such as PLGA, PLLA, ethyl cellulose (EC), and Eudragit. You can use certain low-boiling-point organic solvents in combination with an inert gas for drying. This allows the slurry to be converted into a powder at a lower drying temperature and effectively protects heat-sensitive components.
Inert Loop Spray Dryer vs. Open Loop Spray Dryer

| Dimension | Inert Loop Spray Dryer | Open Cycle Spray Dryer |
| Drying Medium | High-purity inert gas (such as nitrogen), closed-loop circulation | Filtered ambient air, single-pass discharge |
| Solvent Compatibility | Organic solvents (ethanol, acetone, and more) and aqueous solutions | Aqueous solutions only (water as solvent). Handling organic solvents poses extremely high risks and is not recommended. |
| Safety and Explosion Proof | Controlled oxygen environment, oxygen monitoring, interlocks, and inert gas circulation | Usually ambient-air operation. Cannot be processed with organic solvents. |
| Solvent Recovery | Supported (Equipped with a condenser, recovery rate usually >95%) | Not Supported (Evaporated moisture is directly discharged into the atmosphere) |
| Environmental Safety | Excellent. Less risk of organic gas or toxic vapor leakage | Causes environmental pollution and safety hazards if used for volatile materials |
| Cost and Complexity | Higher (Requires gas sealing, nitrogen circulation, oxygen monitoring, and condensation units) | Lower, simple structure, relatively easy maintenance |
| Primary Applications | Pharmaceutical formulations, battery materials research, organic polymers, specialty chemicals | Food, agricultural extracts, pure water-based inorganic ceramics, and routine water-soluble materials |
Inert Gas Spray Dryer vs. Vacuum Spray Dryer
| Dimension | Inert Gas Spray Dryer | Vacuum Spray Dryer |
| Core Mechanism | Instantaneous drying via rapid heat and mass transfer in a nitrogen steam at atmospheric or micro-pressure | Low-temperature drying by lowering the solvent boiling point under high vacuum conditions |
| Drying Speed | Extremely Fast (Completed within a few hundred milliseconds to several seconds) | Relatively Slow (Longer droplet residence time and heat transfer time in a vacuum environment) |
| Particle Morphology | Easily forms uniform microspheres, hollow spheres, or spherical powders with good fluidity | Particle morphology is influenced by a combination of various factors. |
| Solvent Handling | Highly Suitable. Exceptionally efficient for low-boiling-point and high-volatility organic solvents | Can not be used for organic solvents |
| Ultra Heat-Sensitive Materials | Suitable (Protects materials by maintaining extremely short exposure time) | Excellent (Enables evaporation of water at low temperatures) |
| Scale-Up Scalability | Good. Process parameters are straightforward to scale up to industrial closed-loop drying | Scaling up to pilot and industrial scales is difficult, with high costs for maintaining vacuum levels |
Applications of Inert Gas Spray Dryers
Pharmaceutical and API Formulation Research
APIs are often expensive and sensitive to temperature and oxygen, and many pharmaceutical excipients must be dissolved in organic solvents. Inert gas dryers protect drugs from oxidation and can produce microspheres with a uniform particle size distribution while achieving high recovery rates. Inert gas spray dryers are commonly used to prepare inhalation formulations, PLGA drug-loaded particles, solid dispersions of poorly soluble drugs, and self-emulsifying formulations.
Polymer Powder Preparation
Many specialty polymers are insoluble in water and can only be dissolved in solvents such as acetone, tetrahydrofuran (THF), and toluene. An inert gas system can safely remove and recover these solvents while controlling the porosity of the polymer powder. Therefore, inert gas dryers can also be used to prepare conductive polymers, biodegradable polymers, specialty resins, and silicone micropowders, among other materials.
Fine Chemical and Specialty Chemical Development
The R&D of fine chemicals often involves the use of toxic or highly volatile solvents, and these products typically have high added value. Sealed inert gas dryers help prevent the volatilization of toxic vapors. Furthermore, condensation and recovery can reduce the cost of organic solvents and align with the environmental requirements of Green Chemistry. Typical applications include the preparation of organic dyes and pigments, the encapsulation of fragrances and flavorings, and the production of high-grade additives.
Ceramic Powder and Precursor Preparation
Drying with an inert gas ensures the purity of ceramic powders and maintains an oxygen-free environment during granulation, reducing oxidation-induced impurities and preserving mechanical properties after sintering. Inert gas dryers are commonly used in the preparation of silicon carbide (SiC), silicon nitride, and non-oxide ceramics.
Battery Material and New Energy Research
Inert gas drying is used to prepare common materials such as lithium-ion battery cathode materials, solid-state electrolyte powders, silicon-carbon anode coatings, and graphene composites. Some battery materials are extremely sensitive to the oxidation state and purity of metals. Furthermore, many carbon coating processes require the use of organic solvents. As a result, inert gas spray drying is a suitable process for achieving safe solvent evaporation and oxygen-free protection.
How to Choose the Right Inert Gas Spray Dryer?

Processing Capacity and Sample Volume
If you are in the early stages of R&D, or if raw materials are extremely expensive, we recommend choosing a laboratory-scale inert gas dryer. Because laboratory-scale equipment requires smaller sample sizes, it can help you reduce raw material costs. If you need to conduct small-batch production, process validation, or formulation scale-up, you can opt for pilot-scale equipment.
Solvent Type and Condenser Temperature
You need to evaluate the boiling point and flash point of the solvents you use. Some highly volatile, low-boiling-point solvents, such as dichloromethane and diethyl ether, require a condenser with a lower cooling temperature. This ensures that the solvents can be fully condensed and recovered, thereby preventing them from entering the fan and causing a hazard.
Safety and Automation Level
You need to verify whether the inert gas dryer is equipped with an oxygen sensor and whether the system features automatic nitrogen replenishment and automatic interlock shutdown in case of excessive oxygen levels. In the pharmaceutical industry, compliance with GMP/cGMP data traceability requirements is critical. Therefore, you also need to verify the level of intelligence of the PLC. For example, does it support real-time data logging and export?
Material Properties and Particle Size
If you require extremely small particle sizes or a narrow size distribution, you should pay close attention to the type of atomizer. Generally, laboratory and pilot-scale equipment uses two-fluid nozzles. You can select different orifice sizes based on your particle size requirements. If you have other special requirements, you can also opt for a three-fluid nozzle. For viscous materials or those prone to sticking to the walls, you can choose a dryer with an anti-adhesion design, such as an air-sweep system or mirror-polished surfaces.
Footprint
If the inert gas dryer is to be used in a laboratory, you’ll also need to consider its footprint. You can opt for a compact design. This design integrates the condenser unit, inert gas recirculation module, and drying tower onto a single mobile cart, making it better suited for laboratories with limited space. Additionally, you’ll need to confirm whether the laboratory has a high-purity nitrogen source (nitrogen cylinders or a nitrogen generator) and the appropriate power phase configuration.
Yes, our laboratory- and pilot-scale inert gas spray dryers offer exceptional solvent compatibility. Not only can the equipment safely dry flammable and explosive organic solvents such as acetone and ethanol in a closed loop system, but it can also directly process aqueous solutions simply by switching the drying medium or operating mode. Our equipment offers you extremely high utilization rates across various experimental projects.
High-purity nitrogen is currently the most common and economical choice. In closed gas recirculation systems, nitrogen effectively displaces and isolates oxygen within the system, helping prevent the formation of the three elements necessary for combustion and explosion. For the very few highly reactive materials that are prone to chemical reactions with nitrogen, you may also select other noble gases, such as argon (Ar), as a protective medium as needed to help ensure the safety and purity of the materials.
It is ideal for processing heat-sensitive materials. First, after the material is atomized, evaporation occurs within an extremely short period (typically within a few seconds), so the actual heating time is very brief. Second, because organic solvents usually have low boiling points, the equipment can complete drying quickly even at lower inlet temperatures. Furthermore, the oxygen-free environment created by high-purity nitrogen helps prevent material degradation caused by high-temperature oxidation, thereby fully preserving the activity of heat-sensitive APIs, biopolymers, and other components.
Laboratory and pilot-scale equipment places a high priority on preventing cross-contamination. Towers, cyclone separators, and piping typically feature quick-clamp connections and sanitary-grade stainless steel, making disassembly extremely convenient. During cleaning, components in contact with the material can be rinsed with deionized water by manually disassembling and washing them. After cleaning, the internal piping is dried using hot nitrogen circulated through the system, allowing the equipment to be quickly prepared for the next experiment.
Yes, but the feed system must be properly matched to the atomization system. Direct feeding of high-viscosity materials can easily lead to flow difficulties or nozzle clogging. Our inert gas dryer uses a peristaltic pump, combined with a two-fluid nozzle featuring an automatic de-blocking needle, to reduce the risk of clogging. Additionally, you can ensure uniform atomization and rapid drying of viscous materials by appropriately preheating the diluent, increasing the atomization pressure of the compressed nitrogen, or fine-tuning the feed rate.
The key differences between these methods lie in drying speed and the final product form. Freeze drying typically takes several dozen hours and is extremely difficult to use with volatile organic solvents. Inert gas spray drying completes the drying process in just a few seconds. Not only is it much more efficient, but it also directly transforms organic solvent-based materials into microspheres or powders with uniform particle size and good flowability in a single step. It is ideal for rapid formulation screening and sample preparation in the laboratory.
Yes. All of our inert gas dryers come with a one-year warranty, covering manufacturing defects and equipment quality issues under normal operating conditions. You can purchase with confidence. If you need long-term coverage, we also offer extended warranty services (Optional for a fee). Warranty terms are subject to the model and configuration you select. You can also contact us for more details.
Our laboratory inert gas dryers feature a mobile compact footprint, requiring minimal floor space and no complex piping modifications. All you need to provide is a standard power supply (typically single-phase 220V or three-phase 380V, depending on power requirements), a high-purity nitrogen source, and an exhaust vent or auxiliary exhaust line leading to a fume hood. Some inet gas spray dryer models come equipped with a cooling circulator and a nitrogen recirculation blower, eliminating the need for a large industrial chiller.